Polymetron 9582 Dissolved Oxygen System with 4-20 mA Output Communications, 100 - 240 V AC

Polymetron 9582 Dissolved Oxygen System with 4-20 mA Output Communications, 100 - 240 V AC
# de producto: 9582.99.09P4
Precio final Contáctenos

Save Time on Design

A single design source and one product platform means you spend less time searching for design files or configuring components. Create and reuse your optimal design templates.

Accelerate Your Installation

One source, interchangeable electronic components, a common user interface, and one support team make installation faster and less complicated. Quickly and easily transfer user settings between dissolved oxygen loops.

Reduce Training Complexity

A single platform minimises time required to teach and learn product operations, getting new systems in use faster.

Simplify Maintenance and Operation

Common menu guides reduce variability and provide step-by-step procedures for maintenance and calibration. Standard visual alerts across parameters notify operators when troubleshooting is required. Start-up and maintenance time are minimised with pre-mounted membrane cap and factory pre-conditioned sensors.

Contenido de la caja

Controller, mounting hardware, oxygen sensor, temperature sensor, cable, flow-chamber, basic user manual

Especificaciones

Aberturas de los conductos: 1/2" NPT Conduit
Capacidades de comunicación: 5x salidas 4-20mA
Caudal de muestra: 66 - 166
Certificaciones eléctricas: EMC
CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)
Safety
CAN/CSA C22.2 No. 61010-1
Compensación de la temperatura: Automatic in the range of 0 - 45 °C (32 - 113 °F)
Compensación de temperatura: Automático en el rango de 0 - 45 °C (32 to 113 °F)
Comunicación: digital: MODBUS RS232/RS485, PROFIBUS DPV1, HART optional
Condiciones de almacenamiento: -20 °C - 70 °C
Conexión línea de muestra: 1/4" NPT thread (6mm or 1/4" tubing advised)
Contenido de la caja: Controller, mounting hardware, oxygen sensor, temperature sensor, cable, flow-chamber, basic user manual
Funciones de relé: Scheduler (Timer), Alarm, Feeder Control, Event Control, Pulse Width Modulation, Frequency Control, and Warning
Idiomas del manual: Bulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish
Intervalo de mantenimiento: Membrane Lifetime: 6 months depending on sample
Límite de detección mínimo: < 1 ppb
Línea de drenaje de conexión: 8 mm tubing
Longitud de cable: 10 m (33 ft)
Material: Electrodes: Gold cathode, Silver anode; Flow-through cell: Stainless Steel 316L; Membrane: PFA, Sensor Body: Noryl
Material carcasa: Polycarbonate
Aluminium (powder coated)
Stainless Steel
Mediciones: 0 to 2000 ppb (0-2 ppm)
Método de calibración: Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement
Niveles de seguridad: 2
Pantalla: Graphic dot matrix LCD with LED backlighting, transreflective
Peso: 3.2 kg
Protección de la carcasa (IP): IP66 / NEMA 4X
Rango de medición: 0 - 2000 ppb
  0 - 2000 ppb (0-2 ppm)
Rango de temperatura de operación: -20 - 60 °C at 0 - 95% RH (non-condensing)
Relé: Modo operacional: Primary or secondary measurement, calculated value (dual channel only) or timer/scheduler
Relés: Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
Repetibilidad: ± 0,5 ppb o ±5%, lo que sea mayor
Reproducibilidad: ± 0,5 ppb o ± 2% lo que sea mayor
Requisitos de alimentación (Hz): 50/60 Hz
Requisitos de alimentación (voltaje): 100 - 240 V CA
Resolución de pantalla: 240 x 160 pixels
Tamaño de pantalla: 48 x 68 mm
Tiempo de respuesta: For step change 1-40 ppb: <30s
Unidades: mg/L, ppm, µg/L, ppb, mbar, hPa, inch Hg, mmHg